When to apply the external wiring with terminal and without terminal respectively?Is it 6 square below when apply?Is that generally set terminal or no terminal?Welding (pressure) copper terminal when to apply.
1, terminal and no terminal external wiring is to connect the wire to the terminal board terminal post, the quota of work is: opening, inspection, installation, meter disassembly, test, alignment, sleeve insulation tube, pressure welding terminal, wiring;
2. Whether the box is covered with terminals or without terminals depends on the design or construction requirements. If the installation cost of the box includes wiring and terminals, such cost shall not be taken;
3. The section area of the conductor in the quota is 2.5 and 6;
4. Acceptance code for construction quality of building electrical engineering GB 50303-2002 is as follows:
The general project
The connection between the core wire and the electrical equipment shall meet the following requirements:
Single-strand copper core wire and single-strand aluminum core wire with a cross-sectional area of 10mm2 or less are directly connected with the terminals of equipment and appliances;
Multi-strand copper core wires with a cross-sectional area of 2.5mm2 or less shall be connected with the terminals of equipment and appliances after tightening tin lining or connecting terminals;
Multi-strand copper core wire with a cross-sectional area greater than 2.5mm2 shall be connected with the terminal of the equipment or appliance after connecting the terminal, except for the plug terminal of the equipment;Before the multi-strand copper core wire is connected with the plug type terminal, the end is tightened with tin lining.
The multi-strand aluminum core wire is connected with the terminal of the equipment and appliance after connecting the terminal;
No more than two wires are connected to the terminals of each device and appliance.
CNJWY Electronics is dedicated to terminal block R&D and production, welcome old and new friends to consult and discuss cooperation
Contact Person: Mr. Steven Luo
Tel: 8615013506937
Fax: 86-755-29161263
Dual Row 10 Pin Header Connector , Male Pin Pcb Wire To Board Connectors
DIP10 Pin Box Header Connector Contact Resistance 20 MΩ Max Current Rating 1.0AMP
2.54mm Pitch Board To Cable Connectors , Male Pin Board To Wire Connector
Straight Board To Wire Box Header Connector 1.27mm Pitch 34 Pin Gold Flash
2.54mm 10 Ways DIP PCB Wire To Board Connectors Straight Through Hole
2 * 20 Pin PCB Wire To Board Connectors With Latch 1.27 Mm Ejector Header
Black PCB Wire To Board Connectors Gold Flash 1000MΩ Min Insulation Resistance:
Right Angle 26 Pin PCB Wire To Board Connectors Ejector Header Black Color